Get approved

Civil Defence Approvals & Code Compliance

Fire protection drawings and code-compliance reports prepared to Civil Defence requirements, with support through review comments until approval.

Discuss your project
Fire strategy drawings being marked up

Most projects in the Kingdom need Civil Defence approval before permits, occupancy or handover. We review your building against the Saudi Fire Code (SBC 801) and the applicable NFPA standards, prepare submission-ready fire and life safety drawings, and support you in responding to review comments until the approval is issued.

When you need it

  • A new building or extension that needs a permit
  • A change of use, tenant fit-out or renovation of an existing building (SBC 901)
  • Civil Defence comments on a submission that need closing
  • A hotel, hospital, school or mall that must be brought into compliance

What we deliver

  1. 01Code analysis report: occupancy classification, construction type, fire ratings
  2. 02Fire and life safety drawings: compartments, means of egress, fire protection systems
  3. 03Egress calculations: occupant load, exit capacity, travel distances
  4. 04Technical responses to review comments and revised drawings
  5. 05Site inspection support through to final approval

Send drawings for a fee proposal

Codes, standards & tools

  • SBC 801
  • SBC 901
  • SBC 201
  • NFPA 101
  • NFPA 13
  • NFPA 72
  • IBC
Compartment ACompartment BCompartment CProtected stairFire-rated compartment wallFire doorEscape routeFinal exitIllustrative plan — compartmentation & means of escape

How we work

  1. 01Site & drawing reviewBuilding, use and authority requirements
  2. 02Code analysisSBC 801, NFPA and local requirements
  3. 03Drawings & reportA complete, submission-ready package
  4. 04Submission supportResponses to Civil Defence comments
  5. 05Approval & inspectionThrough to final sign-off

Related projects

View experience
Selected projects · Civil Defence Approvals & Code Compliance
ProjectClient / viaLocationScope
Mouwasat Hospital DammamHealthcareDammamFire safety review and Civil Defence approval, fire compartmentation review and inspection, fire door inspection, and engineering analysis of interior and exterior cladding.
Mouwasat Hospital & Polyclinic JubailHealthcareJubailFire compartmentation review and inspection; polyclinic fire safety review and Civil Defence approval.
WeCare CentreHealthcareAfniahDammamFire and life safety review, code compliance and design
Four Seasons Hotel Riyadh at Kingdom CentreHospitalityMNERiyadhFire and life safety design, review and approval.
Taif Inn Hotel (3 basements + ground + 10 floors)HospitalityIjadaTaifFire safety review, Civil Defence approval and CFD model for the atrium.
Novotel Hotel (3 basements + ground + 13 floors)HospitalityAFM ConsultantsMadinahFire and life safety design, review and Civil Defence approval

Talk to a fire engineer

Send us your drawings or tender documents. We reply within one working day.